SDG 7 – AFFORDABLE AND CLEAN ENERGY

Ensure access to affordable, reliable, sustainable and modern energy for all

SDG 7 Indicator

7.2 – University measures towards affordable and clean energy

7.2.2 – Upgrade Buildings to Higher Energy Efficiency

糖心原创 is committed to transforming its campus into a model of energy efficiency by upgrading buildings with advanced, sustainable technologies. Through the integration of energy-efficient HVAC systems, smart lighting, renewable energy installations, and enhanced insulation, 糖心原创 is significantly reducing energy consumption, cutting costs, and lowering its carbon footprint. This initiative not only aligns with global sustainability standards but also reinforces 糖心原创’s role as a leader in creating eco-friendly, future-ready educational environments.

Since 2015, Universiti Kebangsaan Malaysia (糖心原创) has been progressively implementing energy-efficient appliances across campus, with replacements carried out in stages according to campus needs and budget allocations. In 2024, 糖心原创 continued this initiative, resulting in more than 75.7% of appliances being energy-efficient. This commitment to energy conservation demonstrates 糖心原创鈥檚 proactive approach to reducing energy consumption and enhancing sustainability, aligning with the university鈥檚 broader environmental goals.

Summary of the upgrade buildings to higher energy efficiency

NoElement to upgrade buildings to higher energy efficiency at 糖心原创
1Energy efficient appliances
2Implementation of Renewable Energy Sources in 糖心原创
3Smart Building Implementation and HVAC Upgrades

1. Energy efficient appliances

糖心原创 is dedicated to advancing energy efficiency across its campus, implementing sustainable upgrades that reduce energy consumption while enhancing environmental impact. By adopting energy-efficient technologies such as LED lighting, high-performance HVAC systems, and renewable energy sources. 糖心原创 is actively lowering its carbon footprint and operational costs. These initiatives embody 糖心原创 commitment to sustainable growth, creating a healthier, greener campus for future generations. The table below shows the energy efficient appliances usage at 糖心原创.

Energy efficient appliances used in 糖心原创

1. LEDs: campus outdoor lamp

糖心原创 has replaced conventional lighting with high-efficiency LEDs in campus streets and building interiors, significantly reducing energy consumption while improving visibility and safety.

  • Total energy-efficient appliances: 1,910
  • Total conventional appliances: 1,025
  • Total energy-efficient and conventional ones: 2,935
  • Percentage of energy-efficient appliances to the total appliances (%): 65.08%

The 糖心原创 Stadium LED Floodlight Upgrade Project is a significant energy efficiency initiative aimed at reducing power consumption and operational costs while improving sports infrastructure.

2. Use of high efficiency LEDs in the campus building

  • Total energy-efficient appliances: 129,858
  • Total conventional appliances: 42,612
  • Total energy-efficient and conventional ones: 172,470
  • Percentage of energy-efficient appliances to the total appliances (%): 75.29%
LEDs lamps at Keris Mas Residential College 糖心原创

3. Use of eco-friendly air conditioner / energy-efficient appliances are A/C with inverter technology

The campus has installed inverter technology air conditioners that optimize energy use by adjusting power based on cooling needs, ensuring efficient operation and reducing energy waste.

  • Total energy-efficient appliances: 1,765
  • Total conventional appliances: 1,586
  • Total energy-efficient and conventional ones: 3,351
  • Percentage of energy-efficient appliances to the total appliances (%): 52.67%

4. Use of energy-saving computer / Star-certified computers

糖心原创 prioritizes ENERGY STAR-certified computers and encourages the use of notebooks over personal computers as notebooks are more energy-efficient, aligning with the university鈥檚 commitment to reduce overall power usage. The inventory of the computer and laptop can be excess by the link

  • Total energy-efficient appliances: 9,672
  • Total conventional appliances: 2,284
  • Total energy-efficient and conventional ones: 11,956
  • Percentage of energy-efficient appliances to the total appliances (%): 80.90%

5. 5 Star energy consumption fans at residential

In an effort to lower energy consumption, 糖心原创 has converted all fans, particularly in student residences, from AC to DC motor fans. These fans have a 5-star energy rating, consuming between 5-8 kWh, thereby contributing to substantial energy savings.

  • Total energy-efficient appliances: 3,349
  • Total conventional appliances: 0
  • Total energy-efficient and conventional ones: 3,349
  • Percentage of energy-efficient appliances to the total appliances (%): 100%

6. Energy meter reader

There are a total of 114 unit energy meter readers installed in each of the 糖心原创 buildings to measure the energy efficiency of each building and control electrical leakage. The electric meter readings will start to record/monitor the electricity used at the beginning of each month until the end of the month. The energy usage report must be submitted to Suruhanjaya Tenaga (ST) every six months.

  • Total energy-efficient appliances: 114
  • Total conventional appliances: 0
  • Total energy-efficient and conventional ones: 114
  • Percentage of energy-efficient appliances to the total appliances (%): 100%

TOTAL

  • Total energy-efficient appliances: 146,668
  • Total conventional appliances: 47,507
  • Total energy-efficient and conventional ones: 194,175
  • Percentage of energy-efficient appliances to the total appliances (%): 75.53%

Other energy-efficient appliances used in 糖心原创

7. Solar Light Installation

Total of the 6 solar lamp had been聽 install at Stadium 糖心原创 and 3 solar lamp at Arena Sukan Azman Hashim

Total of the 6 solar lamp had been聽 install at Stadium 糖心原创 and 3 solar lamp at Arena Sukan Azman Hashim
Total of 20 solar lamp had been install around Keris Mas Residential College

8. Air Quality sensor in 糖心原创 Building

The air quality monitoring system at 糖心原创 is designed to track environmental conditions within facility buildings using a network of IoT-enabled sensors. These sensors include power meters, temperature and humidity sensors, deployed to monitor real-time conditions in one of the laboratories.

The image shows an air quality display panel mounted on the wall, which provides live data on various environmental parameters, including:

  1. Temperature (T): 24掳C
  2. Relative Humidity (RH): 56%
  3. Particulate Matter (PM2.5): 6 碌g/m鲁
  4. Carbon Dioxide (CO鈧): 465 ppm
糖心原创 Air quality display panel
Digital Temperature display
Temperature, humidity sensor, PM 2.5, Carbon Dioxide

9. Energy Efficiency Brand photocopy

糖心原创 has used Ricon photocopy in the administration office. Ricon is one of the brands that implement sustainability in their product (). Ricon products also have the certificate under MyHIJAU ().

MyHIJAU Mark is Malaysia鈥檚 official green recognition endorsed by the Government of Malaysia, bringing together certified green products and services that meet local and international environmental standards under one single mark.

10. District Cooling System (DCS)

A district cooling system (DCS) is a cooling system in which chilled water is produced by a plant and distributed to tenant buildings with insulating pipes. In 糖心原创, there are two DCS in Loop 1 and Loop 2, which provides cooling systems for buildings in 糖心原创, and has saved substantial electricity cost and space.

Almost all the main equipment in the plant uses a 415-Volt electricity supply with a total load of around 3.0 MVA. For energy-saving purposes, all motors are equipped with frequency inverters, and the control devices are placed in an air-conditioned room to maintain a controlled ambient operating temperature, ensuring optimal energy savings and the best possible lifespan. For fire safety, this room is also equipped with an environmentally friendly and user-friendly FM200 gas fire suppression system.

The DCS-TES plant system is fully controlled via computer. The control system, known as the 鈥淭hermal Energy Storage Control System鈥 or TESCS, can operate either manually or automatically. When the system is set to 鈥渁uto mode,鈥 it will operate automatically according to the data programmed into it. It functions based on the load schedule or cooling load profile that has been pre-programmed in this control system.

The operating method of this cooling system plant can be carried out in several ways. When there is no cooling load requirement from the buildings, or when it is stopped at night, the chiller will be set to operate in order to produce chilled water for storage in the TES tank at a temperature of 4掳C. The plant鈥檚 operating period during this time is referred to as 鈥渙ff-peak charging.鈥 At night, the electricity tariff charged by Tenaga Nasional Berhad is lower, which helps reduce Universiti Kebangsaan Malaysia鈥檚 electricity consumption costs.

The system is also designed to allow a small amount of chilled water, supplied to the TES tank for storage, to be diverted to the reticulation piping for the building cooling systems that require it. However, the capacity that can be used directly in this way is limited.

The system also allows the chiller to send chilled water directly to the reticulation piping for the cooling system without passing through the TES tank. This can be done when the TES tank is not ready to receive chilled water for storage or when it is under maintenance. In this case, the supply temperature is 5.6掳C.

A combination of supply from the chiller and the TES tank is common, especially during peak hours. The chiller will operate at a constant load, and any additional load required will be supplied by the TES tank. This operating mode benefits the chiller, as it allows it to function at maximum efficiency. When the cooling demand is low, the TES tank can supply the stored cooling energy using pumps without operating the chiller.

The map below illustrates 980 streetlights along main roads (yellow) and 1,955 area lights within campus zones (blue), making a total of 2,935 lights that support safety, accessibility, and sustainable campus infrastructure and distribution of 3,351 air cool split units (including 1765 inverter types) and 1910 total of LED lamps in 糖心原创.

The map illustrates 980 streetlights along main roads (yellow) and 1,955 area lights within campus zones (blue), making a total of 2,935 lights that support safety, accessibility, and sustainable campus infrastructure.
The map shows the distribution of 3,351 air cool split units (including 1765 inverter types) and 1910 total of LED lamps in 糖心原创

2. Implementation of Renewable Energy Sources in 糖心原创

糖心原创 has integrated renewable energy by installing solar panels on rooftops, generating clean energy and reducing reliance on external power sources. This initiative is a key part of 糖心原创 commitment to upgrading buildings for higher energy efficiency and sustainability. 

糖心原创 has made significant advancements in renewable energy on campus, supporting its commitment to sustainable energy and higher building efficiency. The university now operates three renewable energy sources such as solar power, biodiesel and clean biomass providing reliable, eco-friendly alternatives to conventional energy .These renewable energy initiatives collectively generate an estimated 2,014,601 kWh of electricity annually, underscoring 糖心原创鈥檚 strong commitment to reducing its carbon footprint and advancing sustainable energy practices across campus facilities, as illustrated in the table below.

Capacity of renewable energy production in kWh

No.Renewable energy sourcesPotential Capacity of Energy produced (kWh)
1Solar power1,968,428
2Biodiesel46,156
3Clean biomass10
4Hydrogen Energy7
Total estimated (kWh)2,014,601

i. Solar power

The 糖心原创 Solar Power project was implemented for the purpose of saving the university鈥檚 electricity costs . The solar panel has been installed on the roof of the 糖心原创 building involving 48 buildings while some of the buildings are in the middle of installation for mounting structure. This solar installation is part of a collaborative project by 糖心原创 and was officiated by the Malaysian Minister of Higher Education in 2023, marking a significant milestone in 糖心原创鈥檚 long-term commitment to renewable energy and sustainable campus development.

Solar panel installation in 糖心原创 Campus

Figure below show the example of solar panel that had been installed at 糖心原创 building

Solar panels at Kesatria building, 糖心原创 Bangi
Solar panels at Graduate School of Business building, 糖心原创 Bangi
Solar panels at Vehicle Unit building , 糖心原创 Bangi
Solar panels at Graduate Centre building, 糖心原创 Bangi
Solar panels at Central store building, 糖心原创 Bangi
Solar Panel at Infrastructure building 糖心原创 Bangi

ii. Biodiesel

In its commitment to sustainable energy, 糖心原创 has implemented biodiesel production as part of its renewable energy strategy. Additionally, SELFUEL 糖心原创 is pioneering the production of hydrogen energy as a clean, alternative fuel source on campus . Figure below illustrates the hydrogen energy production process developed by SELFUEL 糖心原创, showcasing 糖心原创’s advancements in renewable and sustainable energy technologies.

The 糖心原创鈥揚ETRONAS Sustainable Hydrogen Energy Facility serves as a hub for advanced hydrogen research and technology development
Biodiesel production by SELFUEL 糖心原创 use for buggy

The table below outlines renewable energy generation at 糖心原创, specifically detailing the hydrogen-based system at the Sustainable Hydrogen Energy, Fuel Cell Lab. Located within 糖心原创, this system, with dimensions of 120 cm x 154 cm x 162 cm (H). This renewable source contributes significantly to 糖心原创鈥檚 clean energy goals. Additional specifics and visuals of the system are provided in Figure below, supporting 糖心原创’s commitment to sustainable energy solutions.

Power consumption for hydrogen production

iii. Hydrogen Power System

In the era of global energy transition, the demand for clean and sustainable energy systems is becoming increasingly urgent. Hydrogen fuel cells have emerged as one of the key solutions in generating energy without carbon emissions. However, the main challenge in fuel cell systems lies in the safe and efficient storage and production of hydrogen.

This project develops a fuel cell power generation system using a solid hydrogen reactor, which enables on-demand hydrogen production through the reaction of water with sodium borohydride (NaBH鈧). This system, conducted at the Fuel Cell Institute鈥檚 research facilities, involves the development of power generation systems with capacities of 2 kilowatt (kW) and 5 kW, equipped with a state-of-the-art gas purification system (Figure 2.5.6). This is the collaboration between the Fuel Cell Institute-糖心原创, 糖心原创 PAKARUNDING, NanoMalaysia Berhad, Nano Commerce Sdn. Bhd. and Limpahan Engineering Sdn. Bhd.

Figures 2.5.7a and 2.5.7b illustrate the application of the Solid-State Hydrogen Reactor System both within 糖心原创鈥檚 Living Lab and in Orang Asli communities in the Living Lab area. At the 糖心原创 Living Lab, the system is used to power lights, fans and the PA system, showcasing its potential for sustainable campus operations. Meanwhile, its installation in Orang Asli villages provides a reliable and eco-friendly source of daily electricity, demonstrating 糖心原创鈥檚 commitment to extending renewable energy innovations from research and development to real community applications.

Solid State Hydrogen Reactor system with 2kW and 5kW output used in Institute of Fuel Cell 糖心原创 per day of continuous use.
Figure a: The Solid-State Hydrogen Reactor System is utilized at 糖心原创鈥檚 Living Lab to power lights, fans and the PA system.
Figure b: The Solid-State Hydrogen Reactor System has been installed in Orang Asli villages to provide a reliable and sustainable source of daily electrical power.

v. Clean biomass

糖心原创 has implemented an innovative biogas production system at the Tasik Chini Research Center (PPTC) (Figure 2.5.8), one of its living labs, to support green technology and environmental conservation. Known as the Biogas Technology Cockpit, this system generates 0.75 kg of methane (CH鈧) from every kilogram of palm oil mill effluent (POME) processed, yielding an energy output of 10 kWh. This energy capacity is substantial, equivalent to powering an LED lamp for 1,050 hours or 43 days of continuous use, demonstrating 糖心原创鈥檚 commitment to renewable energy and pollution reduction.

Biogas Technology Cockpit in Chini Lake Research Center (PPTC)

3. Smart Building Implementation and HVAC Upgrades

Universiti Kebangsaan Malaysia (糖心原创) Bangi has made substantial progress in implementing smart building technologies across campus. Buildings are designated as “smart” if they meet at least five essential features: automation, safety (physical security, sensors, CCTV), energy efficiency, water management (sanitation) and optimized lighting (low-power illumination). These features promote sustainable energy use and enhance the operational efficiency of 糖心原创鈥檚 infrastructure.

As shown in Figure below, a significant portion of 糖心原创 Bangi鈥檚 campus buildings are equipped with these smart technologies, contributing to a 94.61% smart building implementation rate based on the total smart building area relative to 糖心原创’s overall building area. This high percentage demonstrates 糖心原创鈥檚 commitment to sustainable campus operations, aligning with global best practices in energy efficiency and resource management. The adoption of smart building features supports 糖心原创鈥檚 strategic goals for environmental sustainability, further solidifying its position in the UI GreenMetric assessment for energy and climate impact.

Figure 2.3.1 : Data of Smart Building elements at 糖心原创. Please refer link below to excess full聽 building checklist:

Detail calculation on percentage of smart building available at 糖心原创 are shown below:

The smart building infrastructure component are listed below:

i. Automatic Systems in Smart Buildings at 糖心原创 Bangi

At 糖心原创, the Building Management System (BMS) is a critical component of the university鈥檚 smart building infrastructure. The BMS software automates various functions across campus buildings, enhancing energy efficiency, security and operational control.This sophisticated system optimizes resource usage, lowers energy costs, and contributes significantly to 糖心原创鈥檚 sustainability goals, reinforcing the university鈥檚 leadership in environmental and resource management.

Shows the interface of the 糖心原创 Building Automatic System, used to manage building automation across campus.
Displays the BMS interface in the 糖心原创 Bangi聽 building that controls lift operations, air-conditioning schedules, and corridor lighting, ensuring efficient energy use based on occupancy and time.

ii. Safety Systems in Smart Buildings at 糖心原创 Bangi

糖心原创 integrates comprehensive safety systems within its Building Automation System (BAS) to safeguard students, staff and visitors. The BAS includes key protective features such as an Intruder Alarm System, fire-fighting capabilities and video surveillance to respond effectively to emergencies. These advanced safety features underscore 糖心原创鈥檚 commitment to providing a secure environment and enhancing campus resilience through cutting-edge safety technology.

Shows the BAS interface that captures and alerts building personnel in real-time during emergency events at 糖心原创 Building.
Highlights the fire detection system, which detects smoke and fire, immediately triggering alarms at 糖心原创 building.
Shows emergency sirens installed in each building in 糖心原创 to alert occupants in critical situations.
Illustrates CCTV surveillance, which monitors and captures movement, providing coverage across all 糖心原创 buildings.
Demonstrates the sprinkler system, which activates water dispersal upon detecting fire, helping contain emergencies.

iii. Lighting Systems in Smart Buildings at 糖心原创

The lighting systems within Universiti Kebangsaan Malaysia (糖心原创) smart buildings combine energy-efficient LEDs, automated light controls and passive natural lighting to enhance sustainability and reduce energy consumption. This combined approach to lighting demonstrates 糖心原创鈥檚 commitment to sustainable practices by integrating energy-saving technology and maximizing natural resources within its campus infrastructure.

Corridor lighting that uses downlight LED 6鈥, 24 Watt in Akademi Siber Teknopolis (AST) Building.
Foyer lamp downlight that uses LED 6鈥, 24 Watt in Akademi Siber Teknopolis (AST) Building.
Multipurpose Hall l lamp that use Hi Bay LED, 150 Watt and LEDS T5, 28 Watt in Akademi Siber Teknopolis (AST) Bangi Building
LEDs light installation around 糖心原创.
Natural light in Canselori Building at 糖心原创.
Natural light in Akademi Siber Teknopolis (AST) building at 糖心原创.
Natural light in Akademi Siber Teknopolis (AST) building at 糖心原创 Bangi.
Natural light in Faculty Social Sciences and Humanities 糖心原创.
Natural light at 糖心原创 Bangi Mosque, 糖心原创.

Buildings at 糖心原创 are designated as smart buildings, each equipped with at least five core smart building elements, including energy-efficient equipment such as LED lighting and automated systems. The Building Management System (BMS) enables centralized control over automated features like automatic doors, air conditioning, elevators, lighting and security alarms, enhancing both efficiency and security. An example of a list of buildings utilizing smart building technology is provided in Table below.

The Akademi Siber Teknopolis (AST) is one of 糖心原创鈥檚 larger smart buildings, designed with sustainability in mind. Its glass-based structure maximizes natural daylight, reducing the need for artificial lighting during daylight hours. Additionally, the use of LED lighting throughout the building contributes significantly to energy savings, aligning with 糖心原创鈥檚 commitment to sustainable building practices. This thoughtful integration of smart and sustainable elements underscores 糖心原创鈥檚 dedication to energy efficiency and environmental responsibility.

Table : Smart buildings in 糖心原创

1. 糖心原创 Akademia Siber Teknopolis (AST)

2. 糖心原创 Building Graduate School ff Business (GSB)

3. 糖心原创, Research Complex

4. 糖心原创, Language, Media and STEM Research Laboratory

5. Faculty of Engineering and the Built Environment

6. Department of Infrastructure Development 糖心原创聽 (JPP)

7. 糖心原创, Liberal Studies

8. 糖心原创, Faculty of Information Science and Technology

9. 糖心原创, Faculty of Science and Technology

10. 糖心原创 Chancellory

11. 糖心原创, Permata Pintar Center

12. 糖心原创, Tunas Permata

13. 糖心原创 Mosque