Department of Chemical and Process Engineering
Waters Aquity H-Series
Separate, identify, and quantify components within a complex liquid mixture
ÌÇÐÄÔ´´ – TBA
Non – ÌÇÐÄÔ´´ – TBA
Agilent 7809A
A gas-based separation method to determine the concentration of a substance
ÌÇÐÄÔ´´ – RM200 / Sample
Non – ÌÇÐÄÔ´´ – RM 300 / Sample
Shimadzu TOC-L CSN
Measures the amount of organic carbon in water
ÌÇÐÄÔ´´ – TBA
Non – ÌÇÐÄÔ´´ – TBA
Shimadzu AA 7800
Determine the concentration value of metal elements in a sample
             Element ( Cr, Cu, Ca, Na, Mg, Mn, Pb, Fe, Zn, Ni, Cd)         Element ( Al )
ÌÇÐÄÔ´´Â         RM100 / Element                                      RM 120 / Element
Non – ÌÇÐÄÔ´´Â    RM180 / Element                                      RM200 / Element
Metrohm Compact IC Plus 882
Ion separation method based on ionic charge
              Anion                   Cation                 Anion + Cation
ÌÇÐÄÔ´´Â          RM120 / Sample           RM100 / Sample        RM170 / Sample
Non – ÌÇÐÄÔ´´Â    RM200 / Sample          RM200 / Sample        RM300 / Sample
Agilent 1200 Series
Methods of separating, identifying and measuring components in a solution mixture
Detector Type      Diode Array ( DAD )     Refractive Index ( RID )        RID + DAD
ÌÇÐÄÔ´´Â              RM120 / Sample       RM100 / Sample              RM170 / Sample
Non – ÌÇÐÄÔ´´Â         RM250 / Sample       RM200 / Sample              RM300 / Sample
Shimadzu IRSpirit
Determining the bonds between molecules in a material through the emission of infrared light
                Attenuated Total Reflection ( ATR )   Potassium Bromide Pellet Method ( KBR )
ÌÇÐÄÔ´´Â           RM80 / Sample                     RM130 / Sample              Â
Non – ÌÇÐÄÔ´´Â      RM100 / Sample                     RM150 / Sample             Â
Agilent Cary 60 UV-Vis
Determining the bonds between molecules in a material through the emission of infrared light
                  Absorbance          Transmitten            Reflextance
ÌÇÐÄÔ´´Â              RM60 / Sample       RM60 / Sample          RM60 / Sample
Non – ÌÇÐÄÔ´´Â         RM100 / Sample       RM100 / Sample         RM100 / Sample
Malvern Nano-ZS
Determining the size of particles in a substance in liquid form
                  Particle Size          Zeta Potential          Surface Charge
ÌÇÐÄÔ´´Â              RM50 / Sample        RM80 / Sample          RM80 / Sample
Non – ÌÇÐÄÔ´´Â         RM100 / Sample       RM130 / Sample         RM150 / Sample
Mettler Toledo TGA 2
Measuring the change in weight of a sample as it is heated or cooled, to determine thermal stability, material composition, moisture loss rate, decomposition, oxidation, and to confirm the formation of coatings or composite materials
                 Standard Temperature                  High Temperature
           ( 800 degree Celsius and below )          ( 800 to 1600 degree Celsius )
ÌÇÐÄÔ´´Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â TBAÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â TBA
Non – ÌÇÐÄÔ´´Â Â Â Â Â Â Â Â Â Â Â Â Â Â TBAÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â TBA
Mettler Toledo DSC 1
Testing physical changes (melting, crystallization, decomposition) of a substance based on temperature differences.
                Full Min-Max Temperature                 Standard Temperature
                ( -50 to 500 degree Celsius )               ( 25 to 200 degree Celsius)
ÌÇÐÄÔ´´Â                RM100 / Sample                          RM80 / Sample Â
Non – ÌÇÐÄÔ´´Â           RM200 / Sample                          RM150 / Sample
Micromeritics ASAP 2020 Plus
Determine the surface area of ​​the material, the pores of the material and the adsorption isotherm of a gas on a material
                                       Mesopore
ÌÇÐÄÔ´´Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â RM200 / SampleÂ
Non – ÌÇÐÄÔ´´Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â RM200 / Sample
Kruss EasyDyne
Testing the surface tension of a liquid
                                       Surface
ÌÇÐÄÔ´´Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â RM80 / SampleÂ
Non – ÌÇÐÄÔ´´Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â RM150 / Sample